Comparison MYCOND Tibo Smart 12 vs WetAir WAD-A10L

Add to comparison
MYCOND Tibo Smart 12
WetAir WAD-A10L
MYCOND Tibo Smart 12WetAir WAD-A10L
Compare prices 7Compare prices 20
User reviews
1
0
0
0
TOP sellers
Main
Child lock function. Displays room temperature.
Night mode. The built-in Wi-Fi module allows you to control the dehumidifier from your smartphone.
Main functionhouseholdhousehold
Typecondensingcondensing
Installationfloorfloor
Specs
Capacity12 L/day10 L/day
Power consumption200 W195 W
Recommended room area25 m²20 m²
Power supplysingle-phase (230 V)single-phase (230 V)
Controlstouch controlstouch controls
Control via smartphone
 /via MyCond app/
Voice assistantytn lfyys[ytn lfyys[
Air flow120 m³/h120 m³/h
Dehumidifying operating range30 — 80 % Rh30 – 80 % Rh
Operating temperature range5 – 35 °C5 – 35 °C
Condensate tank volume2 L2 L
Noise level38 dB
RefrigerantR290R290
Features
Functions
hygrostat
fan speed adjustment
timer
anti-freeze mode
drying clothes (turbo mode)
air filter
tank indicator
auto shutdown
drainage
hygrostat
fan speed adjustment
timer
anti-freeze mode
drying clothes (turbo mode)
air filter
tank indicator
auto shutdown
drainage
General specs
Wheels
Display
Dimensions445x255x220 mm445x250x220 mm
Weight10 kg10 kg
Added to E-Catalogfebruary 2023september 2021

Capacity

The nominal capacity of the dehumidifier is the maximum amount of moisture that the unit can remove from the air per day.

For efficient operation, the capacity of the dehumidifier must be no less than the amount of excess moisture that accumulates in the room during the same time. This amount can be calculated using special formulas or calculator programs. However, the results of such calculations are quite approximate, but they can be used in the selection, and for a full guarantee it is worth taking a performance margin of at least 10–20%. If desired, this margin can be more; but note that high performance significantly affects the price, dimensions and energy consumption of the dehumidifier.

As for specific values, entry-level models for small spaces provide less than 25 L/day. Indicators of 26 – 50 L/day can be called average, 51 – 75 L/day — above average; there are also many powerful professional units with a capacity of more than 75 L/day.

Power consumption

Power consumption of the dehumidifier in normal operation.

From a practical point of view, this characteristic is secondary — manufacturers select power in such a way as to provide the necessary operating parameters (performance, air flow, etc.), and when choosing, you should focus primarily on these parameters. However, certain practical points also depend on the power consumption. Firstly, only models of less than 3-3.5 kW can be connected to ordinary household outlets; higher power consumption will require either a 400 V supply (see Power supply) or a direct connection to the panel. However, even power of more than 2 kW is rare in modern dehumidifiers — for most of these devices, the energy consumption is in the range from 500 to 1000 W or from 1000 to 2000 W, and in the most modest models it does not exceed 500 W at all. Secondly, power data may be required to calculate the load on the power grid. Such a need arises mainly for the selection of additional equipment — circuit breakers, AVR, UPS, etc.

Also, note that models with similar performance may differ in power consumption. However, a more economical dehumidifier often costs more, but with regular use, this difference pays off by reducing energy costs.

Recommended room area

The area of the room for which the device is designed. It is the maximum area that this model can effectively handle: the use in smaller rooms is quite acceptable, but the device simply does not have enough performance for a larger space. Also, note that the area is indicated based on a ceiling height of 2.5-3 m — the standard value for residential premises; with a higher ceiling height, the effective area decreases, and it can be recalculated using special formulas.

When choosing by area, it is worth taking a certain margin, but it should not be too large — otherwise, the device will be unnecessarily powerful, bulky and expensive.

Dehumidifying operating range

The range of relative humidity (RH — relative humidity) of the ambient air, in which the dehumidifier is guaranteed to be able to cope with its task and at the same time perform at the level claimed by the manufacturer.

The wider this range — the more versatile the unit, the less likely it is to be in emergency conditions. At the same time, when choosing, it is worth considering the specifics of the application of the dehumidifier. Thus, dehumidifiers are initially designed for high humidity, but the ability to work at 100% relative humidity is not always required. For example, in the cold season, the air coming from the street is "drier" by itself when heated indoors (due to the increase in temperature, the relative humidity drops, although the actual amount of moisture in the air does not change), and even in wet weather, a dehumidifier with a limit of 80-90% may be enough. And the lower dehumidification limit directly depends on the tasks facing the device. If we are talking about living quarters, offices and other places where you need to create conditions that are pleasant for people, then you need to take into account that the most comfortable values for a person concerning humidity are 40-70%. Therefore, for such conditions, it makes no sense to specifically look for a device with a lower limit of less than 40%. But for specific tasks such as drying rooms during repairs, warehousing, etc. lower humidity levels may be needed.

Note that many model...s are quite capable of working outside the operating range, except that the performance may decrease. However, it does not hurt to clarify such an ability according to the official documentation.

Noise level

The maximum noise level produced by the dryer during operation. The lower this number, the more comfortable the use of the unit will be; this is especially true for residential premises. For workshops, warehouses and other similar places, the noise level is not so critical — this type of climate control equipment is often installed in places where there are almost no people, or in the vicinity of such noisy equipment, against which the noise from the dehumidifier can simply be lost. However, for non-residential premises, data on the noise can be useful — for example, to assess the need for special ear protection and other labour protection measures.

Note that this parameter is measured in decibels, and this is a non-linear value: for example, a change of 3 dB approximately corresponds to an increase/decrease in power by 2 times, by 10 dB — by 10 times, etc. Therefore, to assess the noise level, it is easiest to use comparative tables. Here is a simplified table for the range that most modern dehumidifiers fall into.

35 dB — muffled conversation;
40 dB — quiet conversation; the maximum noise level allowed in residential premises during the daytime;
45 — 50 dB — conversation in a normal tone;
55 dB — background sound in the office without special noise sources;
60 dB — loud conversation;
65 dB — city street with average traffic intensity;
70 dB — a conversation of several people in raised tones.