Укр|Eng|Рус
Ukraine
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Dehumidifiers

Comparison Cooper&Hunter CH-D016WDP6 vs Cooper&Hunter CH-D014WD5

Add to comparison
Cooper&Hunter CH-D016WDP6
Cooper&Hunter CH-D014WD5
Cooper&Hunter CH-D016WDP6Cooper&Hunter CH-D014WD5
Compare prices 3Compare prices 5
TOP sellers
Main functionhouseholdhousehold
Typecondensingcondensing
Installationfloorfloor
Specs
Capacity40 L/day33 L/day
Power consumption700 W730 W
Power supplysingle-phase (230 V)single-phase (230 V)
Controlstouch controlspush-button
Voice assistantytn lfyys[ytn lfyys[
Air flow
230 m³/h /195/170 m3/hour/
275 m³/h /225/200 m3/hour/
Dehumidifying operating range35 – 85 % Rh35 – 85 % Rh
Operating temperature range5 – 35 °C5 – 35 °C
Condensate tank volume7 L7 L
Noise level39 dB39 dB
RefrigerantR134AR134A
Features
Functions
hygrostat
fan speed adjustment
timer
drying clothes (turbo mode)
air filter
filter indicator
tank indicator
auto shutdown
hygrostat
fan speed adjustment
timer
drying clothes (turbo mode)
air filter
filter indicator
tank indicator
auto shutdown
General specs
Wheels
Display
Dimensions625x396x286 mm610x380x285 mm
Weight23 kg18.5 kg
Color
Added to E-Catalogaugust 2016august 2016

Capacity

The nominal capacity of the dehumidifier is the maximum amount of moisture that the unit can remove from the air per day.

For efficient operation, the capacity of the dehumidifier must be no less than the amount of excess moisture that accumulates in the room during the same time. This amount can be calculated using special formulas or calculator programs. However, the results of such calculations are quite approximate, but they can be used in the selection, and for a full guarantee it is worth taking a performance margin of at least 10–20%. If desired, this margin can be more; but note that high performance significantly affects the price, dimensions and energy consumption of the dehumidifier.

As for specific values, entry-level models for small spaces provide less than 25 L/day. Indicators of 26 – 50 L/day can be called average, 51 – 75 L/day — above average; there are also many powerful professional units with a capacity of more than 75 L/day.

Power consumption

Power consumption of the dehumidifier in normal operation.

From a practical point of view, this characteristic is secondary — manufacturers select power in such a way as to provide the necessary operating parameters (performance, air flow, etc.), and when choosing, you should focus primarily on these parameters. However, certain practical points also depend on the power consumption. Firstly, only models of less than 3-3.5 kW can be connected to ordinary household outlets; higher power consumption will require either a 400 V supply (see Power supply) or a direct connection to the panel. However, even power of more than 2 kW is rare in modern dehumidifiers — for most of these devices, the energy consumption is in the range from 500 to 1000 W or from 1000 to 2000 W, and in the most modest models it does not exceed 500 W at all. Secondly, power data may be required to calculate the load on the power grid. Such a need arises mainly for the selection of additional equipment — circuit breakers, AVR, UPS, etc.

Also, note that models with similar performance may differ in power consumption. However, a more economical dehumidifier often costs more, but with regular use, this difference pays off by reducing energy costs.

Controls

The type of control provided in the design of the dehumidifier.

The type of control determines how external control elements (buttons, knobs, sliders) interact with the hardware of the unit. There are two options here:

Mechanical. Systems in which the control elements act directly on the individual parts of the dryer. For example, fan speed adjustment (see "Features") in such systems can be carried out using a slider that directly changes the resistance of the resistor in the fan power circuit; the shutdown timer (see ibid.) is a rotary knob with a clock mechanism, etc. The mechanical control is simple and reliable, it is suitable for all basic functions of the dehumidifier and at the same time, it is inexpensive. On the other hand, such systems are inferior in accuracy to electronic ones, and besides, they do not allow many additional features (remote control, display, etc.). Therefore, although this type of control can be found in all categories of dehumidifiers, there are fewer such models on the modern market than electronic ones.

Electronic. Control is carried out through a special electronic circuit: each user action (pressing a button, turning a knob, etc.) is processed by this circuit, and from it control signals are sent to the working elements of the dehumidifier. Such systems are more functional and advanced than mechanical ones. Electronic control is c...onvenient and allows you to use various additional functions — for example, displays and remote controls; and individual parameters can be controlled with very high precision and small adjustment steps. The disadvantages of electronic systems are considered to be higher cost and lower reliability than mechanics, as well as repair difficulty. At the same time, these shortcomings are not so often critical: for example, differences in cost are usually almost imperceptible against the the overall price of devices, and the probability of failure in modern electronics is still very low. Nowadays, it is the most popular type of control among dehumidifiers of all categories. And it can be implemented either by buttons or by touch panel. The second option gives the device a solid look.

Air flow

The maximum amount of air that a dehumidifier can pass through in an hour.

The choice for this parameter depends on the size of the room. It is believed that for effective operation, the dehumidifier must drive through itself an amount of air in an hour that exceeds the volume of the room by 3-4 times; and you can determine the volume of the room by multiplying the area by the height of the ceiling. For example, a 12 m² room with 2.5 m ceilings will hold 12*2.5=30 m³ of air; accordingly, for efficient operation in such a room, a dehumidifier with a capacity of 30*3=90 m³/h, and preferably 30*4=120 m³/h, is required. It is quite possible to choose a unit with a margin for airflow — unless you need to take into account that an increase in performance affects the price and energy consumption. But a too-low value of this parameter is undesirable: such a dehumidifier simply cannot effectively cope with its task.

As for specific figures, relatively low-power models produce up to 250 m³/h, equipment for 251–500 m³/h and 501–750 m³/h can be attributed to the average level, and many units are capable of processing more than 750 m³/h.
Price graph
Cooper&Hunter CH-D016WDP6 often compared
Cooper&Hunter CH-D014WD5 often compared