Укр|Eng|Рус
Ukraine
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers   /   E.C.A.

E.C.A. Gelios 13 HM 13 kW

Photos - Boiler E.C.A. Gelios 13 HM 13 kW
Outdated Product
12 765 
  
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 104; Heat output (kW): 13; Coolant min. T (°C): 40; Coolant max. T (°C): 80; DHW min. T (°C): 35; DHW max. T (°C): 64; Combustion chamber: open (atmospheric); Firebox size: Dimensions (mm): 720x400x330
add to listmy lists
E.C.A. Gelios 13 HM 13 kW
Energy source:gas
Mount:wall, dual-circuit
Boiler power:13 kW, area ~ 104 m²
Combustion chamber:open, flue 110 mm
DHW temperature:from 35 °С, up to 64 °С
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
All specifications
Specifications Gelios 13 HM
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area104 m²
Technical specs
Heat output13 kW
Power supply230 V
Power consumption119 W
Coolant min. T40 °С
Coolant max. T80 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure10 bar
Consumer specs
DHW min. T35 °С
DHW max. T64 °С
"Summer" mode
Circulation pump
Boiler specs
Combustion chamberopen (atmospheric)
Flue diameter110 mm
Max. gas consumption1.58 m³/h
Expansion vessel capacity6 L
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply3/4"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
power outage
water circulation failure
frost protection
More specs
Dimensions (HxWxD)720x400x330 mm
Weight32 kg
Added to E-Catalogdecember 2018
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog E.C.A. 2024 - new products, best sales and most actual models E.C.A..
11 January, 12:25
Тиск води #
anonim
10 December 2022, 01:09
Не запускається після відновлення подачі світла. На екрані «АР» #
Купив квартиру з даним котлом, зараз часто вимикають світло. Котел сам пімля відновлення подачі ел енергії запуститись не може. Гудить і пише «АР» доки не зробити переключення з режиму сніжинка в нуль, і назад у сніжинку. Підкажіть, будь ласка, що таке АР і як це виправити. Дуже дякую!
anonim
8 December 2022, 17:19
Як виправити помилку F4 ? #
Чому вибиває помилку F4 ? Перезавантаження не допомагає. Допоможіть будь ласка.