Ferroli DIVAtech F37 D 37 kW

Photos - Boiler Ferroli DIVAtech F37 D 37 kW
Outdated Product
38 000 
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 296; Heat output (kW): 37; Coolant min. T (°C): 30; Coolant max. T (°C): 90; DHW min. T (°C): 40; DHW max. T (°C): 65; Performance (ΔT=25 °C) (L/min): 21.1; Warm start; Efficiency (%): 93; Combustion chamber: closed (turbocharged)
add to listmy lists
Ferroli DIVAtech F37 D 37 kW
Energy source:gas
Mount:wall, dual-circuit
Boiler power:37 kW, area ~ 296 m²
Combustion chamber:closed, flue 60/100 mm
DHW temperature:from 40 °С, up to 65 °С
All specifications
Specifications DIVAtech F37 D
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area296 m²
Technical specs
Heat output37 kW
Min. heat output12.9 kW
Power supply230 В
Power consumption135 W
Coolant min. T30 °С
Coolant max. T90 °С
Heating circuit max. pressure3 bar
Consumer specs
DHW min. T40 °С
DHW max. T65 °С
Performance (ΔT=25°C)21.1 L/min
"Summer" mode
Warm start
Circulation pump
Boiler specs
Efficiency93 %
Combustion chamberclosed (turbocharged)
Flue diameter60/100 mm / 80/130 /
Inlet gas pressure20 mbar
Max. gas consumption4.2 m³/h
Expansion vessel capacity10 L
Expansion vessel pressure1 bar
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply1/2"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
power outage
water circulation failure
frost protection
More specs
Dimensions (HxWxD)700x400x330 mm
Weight37 kg
Added to E-CatalogNovember 2018
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Ferroli 2025 - new arrivals, bestsellers, and the most relevant models Ferroli.
3
1
1
5
Very successful model
3 October 2013 
I think that based on the fairly low price and the reliability, convenience and comfort that we received, we can call this boiler one of the best today.
Convenient control with a pleasant interface, ease of adjustment, comfortable heating of hot water and heating.
During the time that the boiler was installed, no shortcomings were found in its operation. The only thing is that it is necessary to carry out paid maintenance annually, but this is now a mandatory condition for all boilers.
Romuse Ferroli DIVAtech F24 D more than year i recommend it should buy
if you decide to buy a boiler, ask your friends and not the sellers!
6 January 2016 
eats (it eats and does not consume) gas is just insanely much a year later the engine died - they changed it under warranty, they can’t or don’t know how to set it to minimum consumption in the service now I was able to overcome it by 14 cubic meters a day I use it for the fourth year there were still bad things, but I think it won't be interesting
no benefits other than looks
gluttonous and no qualified service
Read the comment.
17 February 2013 
Great boiler. I recommend choosing a boiler with two heat exchangers, since, unfortunately, the state does not monitor the quality of water, although it should. You can almost forget about cleaning heat exchangers from scale. In addition, this model has a very good electrical board - it can withstand our voltage.
Two separate heat exchangers, price, quality, service.
At this price - no.
D4use Ferroli DIVAtech F24 D more than year
3 out of 10 user review(s) shown
7 more user review(s)
anonim
10 April 2020, 19:19
Question about Ferroli DIVAtech F24 D 
Проблема в котле
Мой котёл Ferroli Divatech F24 D Пишет код F6 и при этом он работает и привосходно греет трубы, только у меня проблема не в этом.
Мой котёл не греет воду, которая идёт в краны.
Подскажите пожалуйста, в чём проблема?
anonim
13 April 2019, 12:15
Question about Ferroli DIVAtech F24 D 
Газовый котел ferroli Divatech f24 D ошибка f7
Включается секунду поработает и выскакивает ошибка f7 и еще небольшая лужа под котлом.давление на 0. Что делать?
anonim
17 July 2018, 22:27
Question about Ferroli DIVAtech F24 D 
После выключения света котел не включается
3 out of 39 question(s) shown