17 820 
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 192; Heat output (kW): 25.6; Coolant min. T (°C): 35; Coolant max. T (°C): 85; DHW min. T (°C): 30; DHW max. T (°C): 60; Efficiency (%): 93.6; Combustion chamber: closed (turbocharged); Firebox size: Dimensions (mm): 751x440x240
add to listmy lists
Alpha CM 24 TF 25.6 kW
25.6 kW
28 kW
32 kW
Energy source:gas
Mount:wall, dual-circuit
Boiler power:25.6 kW, area ~ 192 m²
Combustion chamber:closed, flue 60/100, 80/125 mm
DHW temperature:from 30 °С, up to 60 °С
All specifications
Specifications CM 24 TF
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area192 m²
Technical specs
Heat output25.6 kW
Power supply230 В
Power consumption130 W
Coolant min. T35 °С
Coolant max. T85 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure10 bar
Consumer specs
DHW min. T30 °С
DHW max. T60 °С
Performance (ΔT ~30 °C)11.5 L/min
"Summer" mode
Circulation pump
Boiler specs
Efficiency93.6 %
Combustion chamberclosed (turbocharged)
Flue diameter60/100, 80/125 mm / 80/80 for split flue /
Max. gas consumption1.99 m³/h
Expansion vessel capacity4 L
Expansion vessel pressure1 bar
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply3/4"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
More specs
Dimensions (HxWxD)751x440x240 mm
Weight32 kg
Added to E-CatalogMarch 2013
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Alpha 2025 - new arrivals, bestsellers, and the most relevant models Alpha.
VAID
5 January 2022, 11:36
Question about Alpha CM 24 TF 
На манометре падает давление , утечки в системе не видно , что делать ?
открываю подпитку подымаю давление , но постепенно оно падает, заглянул а снизу видно ржавый подтек,
anonim
10 November 2017, 23:36
Question about Alpha CM 24 TF 
Обозначения
При включении котла,когда он начинает грется на цифровом циферблате мигает буква Е.Батереии свою темпиратуру не нагоняют.Что это означает,какая это ошибка?
Additional features boiler Alpha CM 24 TF:
Filters