Daewoo DGB-100MSC 11.6 kW

Photos - Boiler Daewoo DGB-100MSC 11.6 kW
Outdated Product
$464 up to $465
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 93; Heat output (kW): 11.6; DHW min. T (°C): 35; DHW max. T (°C): 60; Performance (ΔT=25 °C) (L/min): 10.7; Efficiency (%): 92; Combustion chamber: closed (turbocharged); Firebox size: Dimensions (mm): 626x490x242
add to listmy lists
Daewoo DGB-100MSC 11.6 kW
Energy source:gas
Mount:wall, dual-circuit
Boiler power:11.6 kW, area ~ 93 m²
Combustion chamber:closed, flue 80/110 mm
DHW temperature:from 35 °С, up to 60 °С
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
All specifications
Specifications DGB-100MSC
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area93 m²
Technical specs
Heat output11.6 kW
Power supply230 V
Power consumption110 W
Consumer specs
DHW min. T35 °С
DHW max. T60 °С
Performance (ΔT=25°C)10.7 L/min
Circulation pump
Boiler specs
Efficiency92 %
Combustion chamberclosed (turbocharged)
Flue diameter80/110 mm
Inlet gas pressure10 mbar
Max. gas consumption1.14 m³/h
Expansion vessel capacity8 L
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply1/2"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
frost protection
More specs
Dimensions (HxWxD)626x490x242 mm
Weight26 kg
Added to E-Catalogseptember 2014
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog Daewoo 2024 - new products, best sales and most actual models Daewoo.
anonim
29 September 2020, 19:39
При включении горелки хлопает и горит часть горелки #
При включении горелки хлопает и горит часть дальняя горелки от стены до датчика наличия пламени, при перекрытии части забора воздуха перед вентилятором(на половину) горелка горит полностью и при пуске не хлопает.Горелка и форсунки чистые.
anonim
5 August 2019, 10:03
ГВС горелка горит при маленьком напоре воды греет при большом нет #
при увеличении протока воды (кран открыт на полную) температура воды падает до 17 градусов при выставленной на котле 55. Давление газа в норме
anonim
19 March 2018, 06:33
Выдал ошибку Е0. датчик комнатной температуры? что делать? #
3 out of 30 question(s) shown
15 more question(s)
Filters