Nova Florida Delfis Monotermica CTFS 24 23.7 kW
![]() | Outdated Product 28 704 ₴ Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 178; Heat output (kW): 23.7; Coolant min. T (°C): 35; Coolant max. T (°C): 83; DHW min. T (°C): 35; DHW max. T (°C): 57; Performance (ΔT=25 °C) (L/min): 11.1; Efficiency (%): 93.1; Combustion chamber: closed (turbocharged) |
Nova Florida Delfis Monotermica CTFS 24 23.7 kW
Energy source:gas
Mount:wall, dual-circuit
Boiler power:23.7 kW, area ~ 178 m²
Combustion chamber:closed, flue 60/100 mm
DHW temperature:from 35 °С, up to 57 °С
All specifications
Specifications Delfis Monotermica CTFS 24
|
|
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Nova Florida 2025 - new arrivals, bestsellers, and the most relevant models Nova Florida.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Nova Florida 2025 - new arrivals, bestsellers, and the most relevant models Nova Florida.
Before buying a boiler of this brand, I didn’t hear anything about them at all, but since a very competent person gave me advice on purchasing it, I took a chance. Judging by the little experience I have (I installed it only 4 months ago), the device is not bad. I hope there won't be any major problems with it in the future. A fairly powerful turbocharged model with two circuits for heating and hot water supply. This is the most powerful model in the line, my house is not small and it just fit in all the main parameters. First of all, I would like to note the high efficiency of this boiler. With a rated power of 25 kW, it is as much as 93%, which compares favorably with cheaper models from other manufacturers. However, our winters are not always cold (remember the positive December of last year), so this boiler will have to work at nominal value only in very severe frosts or with two open hot water taps. Therefore, it is important that the microprocessor control system is able to correctly modulate the burner flame and thus flexibly change the generated heat output, reducing gas consumption. It is especially pleasant that even at the minimum level of water heating of the heating circuit, the efficiency does not decrease below the level of 90%. The boiler is equipped with a motorized three-way valve and has a large user-friendly control panel with an LCD screen. Does not require a special chimney. The minimum water flow in the hot water circuit is 3 liters per minute. Therefore, it will not work to make hot water in a thin stream, the boiler automation simply will not turn on the circuit heating. The boiler is ignited with a noticeable pop. As far as I understand, this is a normal situation, but still somehow restless from this sound. |
1 out of 2 user review(s) shown
1 more user review(s)
Video reviews