Укр|Eng|Рус
Ukraine
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Air Conditioners

Comparison Cooper&Hunter Arctic CH-S12FTXLA2-NG 35 m² vs Cooper&Hunter Nordic Premium CH-S12FTXN-P 35 m²

Add to comparison
Cooper&Hunter Arctic CH-S12FTXLA2-NG 35 m²
Cooper&Hunter Nordic Premium CH-S12FTXN-P 35 m²
Cooper&Hunter Arctic CH-S12FTXLA2-NG 35 m²Cooper&Hunter Nordic Premium CH-S12FTXN-P 35 m²
Compare prices 42Compare prices 32
User reviews
TOP sellers
Typesplit systemsplit system
Installationwallwall
Nominal capacity BTU1200012000
Recommended room area35 m²35 m²
In box
indoor unit
outdoor unit
indoor unit
outdoor unit
Features
Modes and programs
cooling, heating, dehumidification, ventilation
automode
night mode
emergency heating /+8 °C/
self-cleaning
cooling, heating, dehumidification, ventilation
automode
night mode
emergency heating
self-cleaning
Functions
inverter compressor
timer
auto restart
vertical blinds drive
self-diagnosis
control via smartphone
I Feel (remote with temperature sensor)
inverter compressor
timer
auto restart
vertical blinds drive
self-diagnosis
control via smartphone
I Feel (remote with temperature sensor)
Filters
ionizer
CH 7-SKY Technology /system of 7 filters/
plasma (electrostatic)
 
Performance
Power consumption (cooling/heating)962/953 W770/800 W
Cooling capacity3510 W3520 W
Heating capacity3810 W3900 W
Air flow700 m³/h550 m³/h
Dehumidification1.4 L/h1.4 L/h
Noise level (max/min)42/25 dB39/19 dB
Noise level (outdoor unit)53
Refrigerant typeR32R32
Efficiency
Seasonal cooling SEER7.18
Seasonal heating SCOP5.25.1
Energy efficiency SEER (cooling)A++A+++
Energy efficiency SCOP (heating)A+++A+++
Min. T for cooling mode-15 °C18 °C
Maximum T for cooling mode50 °C52 °C
Min. T for heating mode-25 °C-28 °C
General specs
Displayhiddenhidden
CompressorMitsubishi Electric
Maximum height difference between units10 m10 m
Maximum pipe length15 m20 m
Indoor unit dimensions (WxHxD)894x291x211 mm880x298x218 mm
Dimensions of window/outdoor unit (WxHxD)732x555x330 mm762x540x325 mm
Indoor unit weight11 kg10 kg
Outdoor unit weight24.5 kg28 kg
Color
Added to E-Catalogfebruary 2022december 2019

Filters

Types of additional filters that are standard on the air conditioner (in addition to the simplest mechanical cleaning filters, which are found in all models).

We emphasize that we are talking specifically about the filters supplied in the kit; Some models allow you to separately purchase additional elements for air purification, but this possibility is not taken into account in this case. As for specific options, the most popular in modern air conditioners are ionizers, various antibacterial filters(including catechin elements and UV lamps), devices for fine cleaning (including HEPA filters), antifungal, antiallergenic, deodorizing and formaldehyde filters, and also elements that combine several functions at once (for example, catalytic). Here is a detailed description of each of them:

— Ionizer. The action of the ionizer is based on the saturation of the air with negatively charged ions. They provide a feeling of fresh air, have a bactericidal effect, and are considered beneficial for overall health. One of the advanced types of ionizers are also plasma (electrostatic) filters. Along with the saturation of air masses with useful air ions, they are assigned the task of air purification. Such filters can quite effectively destroy harmful microorganisms, destroy some harmful substances, and trap grains of dust, smoke, soot, etc. — these particles, under the influence of ionized air, themselves acquire a charge and are attracted to the filter plates.

— Fine cleaning. This term usually refers to advanced mechanical filters that provide air filtration at a microscopic level. The specific effectiveness of such devices may vary; it should be clarified separately in each case. Note also that the HEPAs described below are also, in fact, fine filters; however, they use a specific operating principle and are inherently highly efficient. Therefore, the presence of HEPA filters is indicated separately.

— HEPA filter. A special type of mechanical fine filters. Thanks to the special design of the microchannels through which air passes in such a filter, such devices can trap particles much smaller in size than the size of the microchannels. For comparison, the effectiveness of a HEPA filter is assessed by its ability to capture contaminants measuring 0.1 - 0.3 microns (with such particles, such a filter is least effective), while the size of most bacteria starts at 0.5 microns. Based on their effectiveness, such filters are divided into classes; Nowadays, HEPA classes from 10 (retains at least 85% of the mentioned particles) to 14 (filtration efficiency reaches 99.995%) are relevant.

- Catechin. In fact, it is a type of antibacterial filters described below, created on the basis of catechins - natural organic substances with a powerful antioxidant effect. Such filters are highly effective in fighting bacteria and viruses, but they are not cheap; In light of these features, they are separated into a separate category.

- Catalytic. Most often, this term refers to photocatalytic, or “zeolite” filters - devices that operate using a special substance (photocatalyst) and UV radiation. Under the influence of such radiation, the catalyst decomposes the organic matter falling on it into simpler substances - usually water and carbon dioxide. This technology not only allows you to remove harmful impurities from the air (at the level of individual molecules), but also provides a good bactericidal and antiviral effect. Moreover, such a filter requires virtually no maintenance: the photocatalyst is not consumed during operation, and the reaction products freely evaporate outside. On the other hand, the price of such elements is quite high.

- Antibacterial. Various filters designed to destroy bacteria and other harmful organisms - viruses, fungi, etc. The specific operating principle, level of efficiency and maintenance rules for such filters may vary; these details should be clarified in the documentation for the air conditioner. However, if air disinfection is of fundamental importance to you, such a filter will definitely not be out of place. Let us note only two nuances in this regard. Firstly, catechol elements are usually not included in this category, although they have the same purpose (see above); secondly, not every antibacterial filter is capable of effectively fighting viruses - again, it would not hurt to clarify this point separately.
It is also worth considering that no matter how effective the air conditioner filters are, thorough air disinfection is not its main task; specialized devices should be used for these purposes.

- Antifungal. A specialized filter for removing harmful fungi from the air, such as mold. The antibacterial devices described above also have this function to one degree or another; however, this type of filter is much more effective in this regard. On the other hand, the need to intensively fight specifically fungi does not arise so often, and for other cases, the same antibacterial filters are usually quite sufficient. So antifungal elements are used quite rarely in modern air conditioners.

- Anti-allergenic. Filters designed primarily to remove allergy-causing contaminants from the air: pollen (including from indoor plants), dust mites, particles of pet hair, etc. The specific operating principle of such filters may vary and should be clarified separately. Thus, relatively inexpensive air conditioners usually use simple mechanical cleaning, and the term “anti-allergenic” is more of a marketing ploy than a real description of the filter’s specialization. More advanced models often include more advanced technologies - for example, an enzyme filter that breaks down allergens into simple, harmless substances like water and carbon dioxide.

- Ultraviolet lamp. A lamp that processes the air passing through the air conditioner with UV radiation. This treatment provides a bactericidal effect: ultraviolet light neutralizes most bacteria, viruses and fungi. True, in general the efficiency of such lamps is not particularly high; however, they are a great addition to an antibacterial filter. And even without such a filter, the quality of air purification of an air conditioner with a UV lamp will be higher than that of a similar model without such a lamp.
We would like to emphasize that this function should not be confused with the catalytic (photocatalytic) filter described above - UV lamps have a much simpler design and operating principle.

— Deodorizing (charcoal). A specialized filter designed, among other things, to combat unpleasant odors. Acts at the molecular level, allowing ordinary air to pass through and absorbing molecules of substances that create unpleasant odors; Of course, it is also capable of trapping larger particles, such as smoke. Activated carbon is most often used as a filter element - hence one of the variants of the name; There are filters based on other substances, but they also have similar properties. It is worth keeping in mind that in any deodorizing filter the working element must be changed periodically - when its resource is exhausted, it becomes useless and can even emit harmful substances itself.

- Formaldehyde. A specialized filter for removing formaldehyde and some other harmful organic compounds (for example, ammonia, benzene and/or hydrogen sulfide) from the air. The source of such substances can be both external pollution (for example, emissions from industrial enterprises) and some objects in the room itself: new furniture or curtains, some types of floor and wall coverings (immediately after application), spoiled food, cigarette smoke, etc. n. The specific operating principle of filters of this type may vary. Most often, the so-called cryocatalytic element is used, in which the catalyst decomposes organic matter into simpler, harmless components, and then restores its properties due to the cold when the air conditioner operates for cooling. In addition, many catalytic (photocatalytic) filters (see above) have similar capabilities, so one such element can be declared in the characteristics as two types of filters at once - both catalytic and formaldehyde.

In addition to the varieties described above, other types of filters may be found in modern air conditioners, in particular:

— Air purifying. A general name used for different types of filters. This term often denotes the simplest elements of coarse cleaning (for advertising purposes - so that the list of filters in the characteristics is larger). However, there is also another option - devices created on the basis of specific proprietary technologies and which do not fit into any of the varieties described above; such devices can combine several functions simultaneously (for example, fine filtration and antibacterial effect).

— Dust collecting. Most often we are talking about a simple mechanical filter that traps dust and other relatively large particles. Almost all modern air conditioners are equipped with such devices, but in some models the presence of “dust” filters is specified separately - mainly for advertising purposes.

— With vitamin C. A filter that saturates the air with vitamin C. It is believed that this supplement has a positive effect on immunity and skin condition; There is no clear evidence of this, but in conditions of vitamin deficiency, such a device will definitely not be superfluous.

- Preliminary. Mechanical coarse filter installed in front of the main set of filters. Detains relatively large contaminants, preventing them from reaching other filter elements and removing part of the “load” from them. At the same time, the design of the pre-filter is, as a rule, as simple as possible, and its maintenance is limited to periodic shaking or washing.

— “Ionic” (for example, Smart Ion, etc.). As a rule, it is the same electrostatic filter (see above), but presented under one or another brand name.

Power consumption (cooling/heating)

Power consumption of the air conditioner in cooling and heating mode; for models without a heating mode, only one number is given. This parameter should not be confused with the effective capacity of the air conditioner. Effective capacity is the amount of heat that the unit can "pump" into the environment or the room. This item also indicates the amount of electricity consumed by the device from the network.

In all air conditioners, the power consumption is several times lower than the effective capacity. It is due to the peculiarities of the operation of such units. At the same time, devices with the same efficiency may differ in power consumption. In such cases, the more economical models usually cost more, but with continued use, the difference can quickly pay off with less electricity consumption.

Also, two points related to electrical engineering depend on this nuance. Firstly, power consumption affects power requirements: models up to 3 – 3.5 kW can be connected to a regular outlet, while higher power consumption requires a three-phase connection (see below). Secondly, the power consumption is needed to calculate the load on the mains and the necessary parameters of additional equipment: stabilizers, emergency generators, uninterruptible power supplies, etc.

Cooling capacity

The heat output of the air conditioner when operating in cooling mode, in other words, the amount of heat energy that the unit can transfer from the room to the external environment when operating in this mode.

In general, cooling capacityup to 2 kW for modern air conditioners is considered very modest, 2–3 kW is low, 3–4 kW is medium, 4–6 kW is above average, and in the heaviest and most productive models this figure can be 6–8 kW and even more. Also, the conventional unit BTU can be used to denote capacity; in our catalogue, 1 BTU corresponds approximately to 0.293 W, however, for the convenience of choice, some deviations are allowed: for example, the 7000 BTU category includes units with power from 1.8 to 2.3 kW. Also on sale you can find air conditioners for 9000, 12000, 18000, 24000 BTU and more.

As for the choice for this indicator, the simplest formula is as follows: at least 100 W or 1/3 BTU of thermal power should fall on 1 m2 of the area of the room. Thus, to estimate the maximum area served, the power in watts should...be divided by 100, and the power in BTU should be multiplied by three. However, all these calculations are relevant only for standard residential/office premises with a ceiling height of about 2.5-3 m. For other conditions, you need to use a more complex formula, which is the sum of three parameters: 1) Q1 - the heat gain of the room itself, calculated by multiplying the area of the room by the height of the ceilings and the heat transfer coefficient (it ranges from 30 to 40 W, depending on the conditions); 2) Q2 - heat gain from operating equipment (on average, a third of the total power of all electrical appliances); 3) Q3 - heat gain from each person (from 100 W for sedentary work to 300 W for heavy physical exertion). More detailed recommendations regarding such calculations can be found in special sources.

A special case is represented by separately sold outdoor units of air conditioners (see "In box"). In this case, the capacity in cooling mode is the highest heating capacity of the indoor unit (in the same mode, of course) that can be connected to this outdoor unit. For multi split systems, respectively, the total indicator of all indoor units is taken into account.

Heating capacity

The power provided by the air conditioner in heating mode. It is indicated by the amount of thermal energy that the air conditioner can "pump" from the external environment into the room when operating in this mode. The most modest modern units have a heating capacity of 2 – 3 kW or even less, in the most performant it reaches 6 – 8 kW or more.

When evaluating this capacity, the same formulas are relevant that are used in calculating the power of traditional heating. So, for the full heating of an ordinary residential or office space (with ceilings of 2.5-3 m and normal thermal insulation), a thermal power of at least 100 W is required. There are more detailed calculation rules that allow you to calculate the necessary characteristics for other conditions. And if we are talking about a separately sold outdoor unit (see "In box"), then the meaning of this parameter is somewhat different. It indicates the maximum power of the indoor unit that can be connected to this outdoor unit to work in heating mode. For multi split systems, respectively, the total capacity of all indoor units is taken into account.

Recall that most air conditioners are not designed for use as full-fledged heating systems. However, such a unit can be a good addition to the main heating system. At the same time, air conditioners are less expen...sive than electric heaters: the heater has an effective power equal to energy consumption, and the air conditioner consumes much less energy than it supplies to the heated room.

Also note that the unit BTU (more precisely, BTU/hour) can also be used to indicate the effective capacity (including in heating mode). 1 BTU (BTU/h) initially corresponds to 0.293 W, and the numbers in the characteristics of air conditioners correspond to thousands of BTU/h. For example, a 7 BTU air conditioner will produce an effective capacity of 7000 BTU/h, or about 2 kW. Such marking is convenient because BTU can easily determine the recommended area of a standard room (in m2): just multiply the figure indicated in the characteristics by 3. So, in our example, the power of 7 BTU will correspond to an area of 7*3=21 m2.

Air flow

The amount of air that an air conditioner can pass through itself in an hour.

This parameter depends on the power and the overall level of the device, but there is no strict dependence here: models with the same effective capacity may differ in air circulation speed. In such cases, it is worth proceeding from the fact that a higher speed contributes to uniform cooling/heating of the air and reduces the time required to create a given microclimate; on the other hand, higher-performing air conditioners use more energy, are larger and/or cost more.

Noise level (max/min)

The maximum and minimum level of noise produced by the air conditioner during operation; for split and multi split systems (see "Type"), by default, it is indicated for the indoor unit, and the data for the outdoor unit can be specified in the notes.

The noise level is indicated in decibels; this is a non-linear unit, so it is easiest to evaluate this parameter using comparative tables — they can be found in special sources. Here we note that, according to sanitary standards, the maximum level of constant noise for residential premises is 40 dB during the day and 30 dB at night; for offices, this figure is 50 dB, and in industrial premises higher volume levels may be allowed. So it is worth choosing an air conditioner according to this indicator, taking into account where and how it is planned to use it.

As for specific numbers, among the quietest modern air conditioners, there are models with a minimum performance of 23 – 24 dB, 22 – 21 dB, and sometimes even 20 dB or less. However, units at 31 – 31 dB and 33 – 34 dB are not uncommon; such loudness, usually, does not create discomfort in the daytime, but at night it is no longer desirable. However, in some cases, a louder air conditioner may be the best choice: noise reduction affects the cost, sometimes quite noticeably, an...d if the device is not planned to be turned on at night, you can not overpay for additional noise reduction.

Noise level (outdoor unit)

The maximum noise level in decibels (dB) produced by the outdoor (outdoor) air conditioner unit during normal operation.

In household split systems, the noise level from the external unit is usually in the range from 40 to 55 dB. The lower this indicator, the quieter the unit operates and the more comfortable it is to use. Sanitary standards require the noise level for residential buildings from permanent sources to be no higher than 40 dB during the day and 30 dB at night, and in offices background noise of up to 60 dB is completely acceptable. The easiest way to estimate specific noise levels is using comparative tables. So, 40 dB is the level of a quiet conversation or TV at medium volume, 50 dB is approximately the normal tone of human speech, and 60 dB is the level of a loud voice. More detailed data can be found in special sources.

It is important to note that indoors the background noise level from the outdoor unit will be significantly less than outdoors. However, if the noise does not bother you when the air conditioner is running, this does not mean that it does not bother your neighbors. With open windows, the external unit can become a fairly strong source of noise. Therefore, for apartment housing stock it is advisable to give preference to low-noise models of climate control equipment.

Seasonal cooling SEER

The seasonal SEER cooling factor provided by the air conditioner.

The meaning of this parameter is similar to the cooling coefficient — EER (see above): we are talking about the ratio of useful power to spend, and the higher the coefficient, the more efficient the device is. The difference between these parameters lies in the measurement method: EER is measured for strictly standard conditions (outside temperature +35 °C, workload 100%), while SEER is closer to reality — it takes into account seasonal temperature fluctuations (for Europe) and some other specific points, such as the increased efficiency of inverter compressors. Therefore, since 2013, it is customary to use SEER as the main parameter in the EU; this parameter was also adopted for air conditioners supplied to other countries with a similar climate.

Seasonal heating SCOP

Seasonal heating coefficient SCOP provided by the air conditioner.

Like the COP (see above), this parameter describes the overall efficiency of the air conditioner in heating operation and is calculated by the formula: thermal (useful) power divided by electricity consumption. The higher the coefficient, the more efficient the device, respectively. And the difference between COP and SCOP is that COP is measured under strictly standard conditions (outside temperature +7 °C, full workload), and SCOP takes into account seasonal temperature fluctuations (for Europe), changes in air conditioner operating modes, the presence of an inverter and some other options. Thanks to this, SCOP is closer to real indicators, and since 2013 this coefficient has been taken as the main one in the territory of the European Union. However, this parameter is also used for air conditioners supplied to other countries with a similar climate.
Price graph
Cooper&Hunter Arctic CH-S12FTXLA2-NG often compared
Cooper&Hunter Nordic Premium CH-S12FTXN-P often compared