Укр|Eng|Рус
Ukraine
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers   /   Bosch

Bosch Gaz 7000 ZSC24-3MFA 24 kW

Photos - Boiler Bosch Gaz 7000 ZSC24-3MFA 24 kW
Outdated Product
24 228 
Energy source: gas; Installation: wall; Type: single-circuit (heating only); Heating area (m²): 180; Heat output (kW): 24; Coolant min. T (°C): 40; Coolant max. T (°C): 88; Combustion chamber: closed (turbocharged); Firebox size: Dimensions (mm): 850x400x370; Weight (kg): 38;
add to listmy lists
Bosch Gaz 7000 ZSC24-3MFA 24 kW
24 kW
35 kW
Energy source:gas
Mount:wall, single-circuit
Boiler power:24 kW, area ~ 180 m²
Combustion chamber:closed, flue 60/100 mm
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
All specifications
Specifications Gaz 7000 ZSC24-3MFA
Main
Energy sourcegas
Installationwall
Typesingle-circuit (heating only)
Heating area180 m²
Technical specs
Heat output24 kW
Power supply230 V
Power consumption91 W
Coolant min. T40 °С
Coolant max. T88 °С
Heating circuit max. pressure3 bar
Consumer specs
"Summer" mode
Circulation pump
Boiler specs
Combustion chamberclosed (turbocharged)
Flue diameter60/100 mm / 80/80 for split flue /
Max. gas consumption2.8 m³/h
Expansion vessel capacity8 L
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
power outage
water circulation failure
frost protection
More specs
Dimensions (HxWxD)850x400x370 mm
Weight38 kg
Added to E-Catalogaugust 2010
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog Bosch 2024 - new products, best sales and most actual models Bosch.
Add Review
Виктория
19 November 2012, 15:07
Как подключить??? #
Подскажите!!! Как подключить на контур водоснабжения теплый пол, уже поставили насос и клапан для спуска воздуха..... но почемуто не работает.....
Может в котле стоит какаято заглушка????
И еще вопрос!!!
Почему падает давление в системе отопления, разве контура соединены????
Помогите плиз..... скоро зима.....
anonim
30 September 2014, 08:22
Подключают на контур бойлера систему"тёплый пол"? #
Хочу разделить контура отопления:радиаторный контур оставить на основном отоплении котла, а теп.пол и бассейн на контур предназначенный для косвенного бойлера.Можно это осуществить и как лучше.Заранее спасибо.