2E 2E-VP-3K24
2E 2E-VM-2K24
2E 2E-VP-3K242E 2E-VM-2K24
from 9 699 ₴
Expecting restock
Compare prices 3
TOP sellers
Main
PWM (PWM) controller
MPPT controller
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Efficiency90 %93 %
AC input/output
Rated output power3000 VA2000 VA
Rated power3000 W2000 W
Peak power
6000 W /5 сек/
4000 W /5 сек/
Output current70 А65 А
Output voltage waveformpure sine wavepure sine wave
Input (DC)
Battery connection voltage24 V24 V
Max. input current40 А
Battery
Max. input power1.2 kW1 kW
Max. input power1 kVA
Operating voltage range170 – 280 V170 – 280 V
MPPT controller+
Features
Output
UPS function /10 мс/
UPS function /10 мс/
Control interfaces
USB
RS232
USB
RS232
Protection
 
Overload protection
Short circuit protection
Overload protection
General
Operating temperature0 °C ~ +50 °C-10 °C ~ +50 °C
Dimensions420x390x193 mm355x250x122 mm
Weight7.8 kg5.6 kg
Added to E-Catalogapril 2023april 2023

Efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Rated output power

The inverter's rated output power, expressed in volt-amperes (VA). This is essentially the same as power in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Output current

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Max. input current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Max. input power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Max. input power

The maximum allowable input power from solar panels, expressed in kilovolt-amperes (kVA). Essentially, this indicator is similar to power in watts (kW).

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

MPPT controller

Built-in Maximum Power Point Tracking system for tracking maximum power points of photovoltaic modules of solar panels. It determines the most optimal ratio of voltage and current taken from solar panels, thereby ensuring maximum performance of individual strings (chains of panels connected in series). The MPPT controller will be useful in any external changes in weather conditions, as a result of which generation from solar panels will be carried out even in cloudy weather. Modern inverter models contain from 1 to 6 MPPT trackers, which allow you to connect several fields with different orientations and inclinations, thereby eliminating the mutual influence of one field on another. Each output of the MPPT controller is designed to connect one string.