Comparison APC Back-UPS Pro BR 900VA BR900G-GR 900 VA vs APC Back-UPS Pro 900VA BR900G-RS 900 VA

Add to comparison
APC Back-UPS Pro BR 900VA BR900G-GR 900 VA
APC Back-UPS Pro 900VA BR900G-RS 900 VA
APC Back-UPS Pro BR 900VA BR900G-GR 900 VAAPC Back-UPS Pro 900VA BR900G-RS 900 VA
Compare prices 19Compare prices 2
TOP sellers
Model differences: BR1500G-GR supports external battery connection, while BR900G-GR and BR1200G-GR do not.
Typesmartsmart
Form factorstandard (Tower)standard (Tower)
Full load operating time4.38 min4.6 min
Half load operating time16.18 min16.1 min
Switching to battery8 ms8 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range176 – 294 В156 – 300 В
Max. current8 А8 А
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Peak output power900 VA900 VA
Rated output power540 W540 W
Efficiency97.4 %
Output waveformsimilar to a sinusoid (approximated)similar to a sinusoid (approximated)
Output frequency50/60 Hz47 – 63 Hz
Redundant sockets33
Non-redundant sockets22
Socket typetype F (Schuko)type F (Schuko)
Battery
Total battery capacity7 Ah7 Ah
Number of batteries12
Full charge time480 min480 min
Cold start
Protection
Protection
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
Fuseautoauto
Surge protection613 J613 J
Control interfaces
USB
USB
General
Screen
Operating temperature0 – 40 °C0 – 40 °C
Noise level45 dB45 dB
Dimensions (HxWxD)250х100х382 mm250x100x382 mm
Weight10.7 kg10.7 kg
Added to E-Catalogoctober 2021october 2018
Glossary

Full load operating time

UPS continuous operation time from a fully charged battery when connected to a load with a power equal to the UPS output power (maximum or effective, depending on the type of load, see the relevant paragraphs for details). For a UPS designed to work with a home or office PC, a time of about 10-15 minutes is considered sufficient, this is enough to save data and complete work. To power servers, it is worth using devices with an operating time of 20 minutes or more.

Half load operating time

UPS continuous operation time from a fully charged battery when connected to a load with a power equal to half the output power of the UPS (maximum or effective, depending on the type of load, see below for details). The operating time with such a load is much longer than for a full load, and even in the simplest models it can reach 20-30 minutes.

Input voltage range

In this case, the input voltage range is implied, in which the UPS is able to supply a stable voltage to the load only due to its own regulators, without switching to the battery. For redundant UPSs (see "Type") this range is quite small, approximately 190 to 260 V; for interactive and especially inverter ones, it is much wider. Some UPS models allow you to manually set the input voltage range.

Efficiency

Efficiency (coefficient of performance) in the case of a UPS is the ratio of its output power to the power consumed from the network. This is one of the main parameters that determine the overall efficiency of the device: the higher the efficiency, the less energy the UPS wastes (due to heating parts, electromagnetic radiation, etc.). In modern models, the efficiency value can reach 99%.

Output frequency

The frequency (frequency range) of the AC voltage output by the UPS. For computer technology, the frequency range of 47-53 Hz is considered normal, although the smaller the deviation from the 50 Hz standard, the better. On the other hand, in some UPS models, this frequency can be automatically synchronized with the frequency of the mains — so the power supplied to the load will not differ regardless of whether the load is powered by the mains or from the battery. In this case, a wider frequency range, on the contrary, is more desirable.

Number of batteries

The number of batteries supplied with the UPS.

In general, this parameter is more of a reference than practically significant: the number of batteries is selected in such a way as to provide the desired performance — primarily the time of continuous operation. First of all, it is worth paying attention to such characteristics when choosing.