Ukraine
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison Must PV19-6048 EXP vs Must PV18-1012 VPM

Add to comparison
Must PV19-6048 EXP
Must PV18-1012 VPM
Must PV19-6048 EXPMust PV18-1012 VPM
Compare prices 40Compare prices 13
User reviews
0
1
0
0
TOP sellers
Device typehybrid inverteroff-grid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency92 %98 %
AC input / output
Rated power6000 VA1000 VA
Rated power6000 W1000 W
Peak power12000 W2000 W
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage48 В12 В
Number of battery inputs1 шт1 шт
Maximum charge current120 А70 А
Solar PV panels
Max. power6 kW0.63 kW
Operating voltage PV150 – 450 В15 – 105 В
Controller1xMMPT
Number of strings1
Features and control
Functions
UPS function
generator connection
parallel connection
UPS function
generator connection
Control interfaces
USB
LAN (RJ45)
USB
RS485
Protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
General
Displaymonochromemonochrome
Coolingactive (fans)active (fans)
Casing protection classIP20
Operating temperature0 °C ~ +50 °C0 °C ~ +50 °C
Dimensions505x309x147 mm225x355x92 mm
Weight9.5 kg5 kg
Added to E-Catalogoctober 2024march 2023
Glossary

Device type

Autonomous inverter. Voltage and power converters that are not connected to an external electrical network. They are supposed to be used as part of autonomous photovoltaic systems - such inverters generate electricity, which is spent exclusively for the needs of the household. It can be consumed directly by household appliances or accumulated in batteries. This type of inverter is often called off grid.

Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.

Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the...energy accumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.

Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.

Maximum efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Connection voltage

The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used: 12 V, 24 V and 48 V.

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Max. power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.
Price graph
Must PV19-6048 EXP often compared
Must PV18-1012 VPM often compared