Growatt SPE 6000TL HVM-G2
Growatt SPF 6000 ES Plus
Growatt SPE 6000TL HVM-G2Growatt SPF 6000 ES Plus
Compare prices 2Compare prices 26
TOP sellers
Device typehybrid inverteroff-grid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency96.5 %93 %
Euro efficiency95.5 %
AC input / output
Rated power6000 VA6000 VA
Rated power6000 W6000 W
Peak power12000 W
Rated AC current26.1 A
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage48 В48 В
Number of battery inputs1 шт1 шт
Maximum charge current100 А
Solar PV panels
Max. power8 kW8 kW
Operating voltage PV60 – 450 В120 – 450 В
Controller2xMMPT2xMMPT
Number of strings21
Features and control
Functions
UPS function
generator connection
built-in monitoring
UPS function
generator connection
parallel connection
Control interfaces
Wi-Fi
Wi-Fi
Protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displaycolourmonochrome
Coolingactive (fans)passive
Casing protection classIP20IP20
Operating temperature-20 °C ~ +50 °C0 °C ~ +55 °C
Dimensions460x422x125 mm395x460x132 mm
Weight13.5 kg13.5 kg
Added to E-Catalogfebruary 2025july 2024
Brief conclusions of the comparison inverters

Price graph
Growatt SPE 6000TL HVM-G2 often compared
Growatt SPF 6000 ES Plus often compared
Glossary

Device type

Autonomous inverter. Voltage and power converters that are not connected to an external electrical network. They are supposed to be used as part of autonomous photovoltaic systems - such inverters generate electricity, which is spent exclusively for the needs of the household. It can be consumed directly by household appliances or accumulated in batteries. This type of inverter is often called off grid.

Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.

Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the...energy accumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.

Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.

Maximum efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Euro efficiency

The European inverter efficiency is measured based on several load values (e.g. 10%, 30%, 50%, 100%), which better reflects the actual operating conditions of the device. Indeed, in fact, inverters rarely operate at full power in constant mode. To calculate the Euro index, the weighted average of the inverter efficiency at different load levels is taken into account. Note that there is no single generally accepted formula here - it may vary depending on the specific standard or equipment manufacturer. Nevertheless, Euro efficiency allows you to more accurately assess the efficiency of the inverter under conditions of partial and full power use

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Number of strings

Strings in solar energy are chains of panels connected in series. With this connection method, the voltage of the solar panels is summed up, and the current remains constant, which allows you to significantly increase the power generation capacity while maintaining a fairly low current and without the need to use large-section wires.

Specifically, this paragraph indicates the maximum number of strings that can be connected to the inverter for solar panels.

Functions

UPS function. Inverters with a UPS function automatically switch to battery-powered mode when there is insufficient power generation from solar panels or in cases where the main power source is disconnected. This ensures load redundancy. Note that switching may not occur instantly, but with a certain delay (about 10-30 ms).

Connecting the generator. Inverters that support the generator connection function significantly increase the reliability and efficiency of autonomous solar energy systems. In practice, the function can be implemented in several basic ways. First, the system can automatically turn the generator on and off depending on the battery charge level or current power consumption, ensuring efficient use of resources and minimizing fuel consumption. Secondly, switching the load to the generator can be carried out when there is a shortage of electricity generation from solar panels. And thirdly, the generator can be used to maintain an optimal battery charge level so that the system is in full readiness at any time.

Parallel connection. The inverter has special connectors through which two or more devices can be connected to a single electrical network. Parallel connection is used when one inverter is not able to pull the entire load from solar panels and the input power exceeds the capabilities of the device itself.

...href="/en/list/598/pr-50306/">Built-in monitoring. The presence of a built-in monitoring module on board the inverter, which collects information about the productivity of solar panels, allows you to monitor energy production and consumption, as well as monitor the performance of the system as a whole. Moreover, these parameters can often be viewed and controlled in real time (including through a mobile application for a smartphone). The monitoring module is usually connected to the Internet via a Wi-Fi network.