APC Back-UPS ES 700VA BE700G-RS 700 VA
![]() | Outdated Product 5 599 ₴ Quite a classic uninterruptible power supply of a backup type (Offline), which can be conditionally classified as a mid-range solution. The active power of the device is 405 watts. At half load, the APC Back-UPS ES 700VA provides approximately 12 minutes of runtime. The output signal is an approximate sinusoid. There is an input voltage stabilizer (range 180-266 V). The maximum input current is 10 A. Also note that the uninterruptible power supply has 8 sockets, of which only 4 are used for backup power. However, this model can also be used as a surge protector. In the role of indication, LED and sound notification are used. The UPS can be used to protect the RJ-45 communication line. Each time the device is turned on, a self-diagnosis is performed — the analysis system will notify the adm...inistrator about the need to change the battery pack. A maintenance-free lead-acid AGM battery with a sealed case and a thick electrolyte is used as a battery. The UPS during operation has an acceptable noise level (up to 45 dB). The housing does not require rigid fixation for installation. |
APC Back-UPS ES 700VA BE700G-RS 700 VA 550 VA 700 VA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Quite a classic uninterruptible power supply of a backup type (Offline), which can be conditionally classified as a mid-range solution. The active power of the device is 405 watts. At half load, the APC Back-UPS ES 700VA provides approximately 12 minutes of runtime. The output signal is an approximate sinusoid. There is an input voltage stabilizer (range 180-266 V). The maximum input current is 10 A.
Also note that the uninterruptible power supply has 8 sockets, of which only 4 are used for backup power. However, this model can also be used as a surge protector. In the role of indication, LED and sound notification are used. The UPS can be used to protect the RJ-45 communication line. Each time the device is turned on, a self-diagnosis is performed — the analysis system will notify the administrator about the need to change the battery pack. A maintenance-free lead-acid AGM battery with a sealed case and a thick electrolyte is used as a battery. The UPS during operation has an acceptable noise level (up to 45 dB). The housing does not require rigid fixation for installation.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog APC 2025 - new arrivals, bestsellers, and the most relevant models APC.


2 0 2 5 |
через данное добро у меня на работе подключено следующие устройства: комп моноблок, принтер, сканер, роутер, все это у меня примерно на 450 Вт в принципе почти идеальная для него нагрузка, и по идее выдавать должен почти максимальное время работы в 12 мин, в реальности работает 7-8 примерно. Радует кончено же большое наличие розеток на нем, хотя в моем случае это всего лишь 4, у кого системник, моник и т.д. у тех будет поболее нагружено, по внешнему виду большой и тяжелый, спрятать сильно не выйдет. Но все же хорошо что есть в нем защита от перегруза, от помех.. каких не знаю... в целом очень неплохо работает уже годик спустя.. как хорошо стали держать батарее сказать не могу свала богу давно не помогал он мне. недостаток это время работы, мощь есть время указанное не выдает. по начине, нет стабилизатора встроенного, за такие бабки должен быть, а то когда идет перегруз такой звук как будто он сейчас взорвется. ааа еще на счет розеток, есть розетки на нем просто как обычная розетки без поддержки их при выключении. пару первых раз не понял почему не срабатывает. |