Укр|Eng|Рус
Ukraine
Catalog   /   Home & Renovation   /   Electrical Equipment   /   Surge Protectors & Extension Leads

Comparison REAL-EL RS-8 Protect 5m vs REAL-EL RS-6 Extra 1.8m

Add to comparison
REAL-EL RS-8 Protect 5m
REAL-EL RS-6 Extra 1.8m
REAL-EL RS-8 Protect 5mREAL-EL RS-6 Extra 1.8m
Compare prices 35Compare prices 32
User reviews
0
0
1
0
TOP sellers
Main
6 sockets, individual switches for each. Short circuit and overload protection. Protective curtains. Varistor. Wall mount.
Product typesurge protectorsurge protector
Specs
Cable length5 m1.8 m
Max. power3680 W2300 W
Max. load16 A10 A
Max. energy absorption350 J350 J
Wire section1.5 mm²
Operation indicator
Power switchgeneralcommon and for each outlet
Connection
Plug typeon camera flasheson camera flashes
Grounded sockets (type F)86
Protection
 
 
voltage drop
 
 
short circuit
overload
 
voltage surges (varistor)
automatic fuse
Design features
Safety socket cover
Wall mount
Outlets locationin two rows
Socket plugsangledangled
Size100x40x210 mm330x40x70 mm
Color
Added to E-Catalogmarch 2023may 2016

Cable length

The length of the cable used to connect the surge protector to the network.

The longer the cable, the farther from the outlet you can install the device. On the other hand, a long cable can be inconvenient over short distances. Models on a coil are deprived of this drawback (see "Type"), this moment is compensated by the actual presence of the coil, but they differ in large dimensions and heavy weight. So when choosing, it is far from always worth chasing the maximum length of the wire.

Max. power

The highest power consumption of the connected devices that the surge protector can tolerate without consequences (to be more precise, with which it can work indefinitely without overloads, overheating, etc.).

This limitation is due to the fact that the higher the power at the same voltage, the higher the current passing through the equipment (in this case, through the surge protector); and off-design currents can lead to breakdowns and even accidents. And although in order to avoid these consequences, modern filters often provide various types of protection (see above), however, the operation of protection is still an emergency situation that is best avoided. Therefore, it is worth choosing a model according to this parameter in such a way that the maximum filter power is at least not lower than the total power consumption of the load. And it is best to have a margin of 20 – 30% — this will give additional guarantees in case of various deviations in the operation of the connected equipment.

Separately, it is worth highlighting the situations when the filter is planned to be used for the so-called reactive load — electrical appliances that widely use circuits on capacitors and/or inductors, for example, power tools or refrigeration units. The total power consumption of such devices (written in volt-amperes) can be much higher than the active power (which is indicated in watts). The recommended line filter power in such cases is calculated using special...formulas that can be found in the relevant sources.

Max. load

The maximum current that the surge protector can pass through itself for an unlimited time without the risk of overheating, breakdowns and other troubles.

This parameter is directly related to the maximum power of the filter (see above): power is the current multiplied by the voltage. Thus, for example, for a standard 230 V model with a maximum power of 2200 W, the maximum load will be 10 A. Note that the characteristics of modern filters may not correspond to such calculations — for example, the same 10 A can be claimed for a 2500 W model . However, this is not something extraordinary: the difference in figures may be due to active and reactive power (see "Maximum power"), the characteristics of single-phase filters (without 400 V sockets, see above) can be given both for 230 V, so for 230 V and even 240 V, figures may be rounded for readability, etc.

Anyway, the practical value of the maximum load is the same as the maximum power: it should not be less than the current supplied to the connected electrical appliances (otherwise the protection may trip, or even break). And they use this parameter, along with the maximum power, because in some cases it is easier to evaluate the characteristics of the load (and filter requirements) in terms of current consumption, and not in terms of power.

Wire section

The cross-sectional area of the wire used to connect the filter to the network. The larger the cross-sectional area, the thicker the wire, the more reliable it is and the more current it can pass without overheating. Accordingly, thick wires ( 1.5 mm² and 2.5 mm²) are a must for high power devices. At the same time, modern manufacturers, usually, choose the cross-sectional area in such a way as to guarantee the safe operation of the filter at the claimed maximum power (see above). Therefore, in fact, a model with a thicker cable than other similar devices should be chosen if it is supposed to be used in unstable networks in which power surges often occur. If the cross-sectional area seems too small for you ( 0.75 mm² or 1 mm²) for the claimed power, there are special formulas that allow you to check the validity of such doubts.

Power switch

Switch on the body. This function allows you to turn off the power to the load without disconnecting the filter itself from the mains — in other words, it eliminates the need to once again remove the filter plug from the outlet and insert it back. Most often, the switch controls all filter outlets, however, there are models where some of the connectors are bypassed and are always energized, regardless of the position of the switch.

A switch for each outlet. This feature makes it easier to manage the power of connected devices: unplugging and plugging individual outlets is usually easier and faster than unplugging and plugging back in. Thus, electrical appliances used with such a filter can be kept constantly connected to it, turning off and on individual outlets as needed.

— Switch for each circuit. The function is used in models with numerous outlets. Allows you to simultaneously disable half of them, leaving the rest working. It combines the convenience of the points listed above and at the same time does not clutter up the device with unnecessary switches.

It is also worth noting that there are models that combine both a switch on the case and a switch for each outlet.

Grounded sockets (type F)

The number of sockets with type F grounding, provided in the design of the mains filter.

In this case, we are talking about full-size European type F sockets with metal ground clamps on both sides at the edges of the socket. The "socket" in this case means a CEE 7/4 ("Schuko") standard plug. Grounding is required for the safe operation of some types of electrical appliances, in particular, washing machines and other machines that work with water, refrigerators, computers, audio equipment, etc. A detailed list can be found in the reference literature. If you plan to connect such devices through the filter, this filter must have sockets with grounding.

Protection

Short circuit protection. Short circuit (short circuit) protection system — situations when the impedance in the circuit drops sharply, for example, due to a metal object falling between the socket contacts. It reacts to a sharp increase in current and opens the circuit, allowing you to avoid damage and fire equipment.

Voltage drops protection. Protection against power surges in the network. A filter with this function is able to completely cut off power that exceeds the allowable rate set by the manufacturer, protecting the load from damage. Note that the surge protector is not able to replace a full-fledged stabilizer or voltage relay; however, in more or less high-quality networks that are not subject to strong fluctuations, a filter is quite enough.

Overload protection. In this case, overload means a situation when the load power exceeds the values \u200b\u200ballowed for a given network filter. This situation is similar to the short circuit described above — high currents go through the filter; however, overload has its own specifics, so protection against it can be provided as a separate system. However, the principle of operation of such systems is classic: when the permissible power is exceeded, it turns off the power, preventing breakdowns and fires.

Varistor protection. A kind...of protection against short-term power surges in the network, built on varistors — variable impedance resistors. The impedance of such a resistor under normal conditions is in the millions of ohms, but it drops sharply if the input voltage increases above a certain value. Due to this, in normal mode, the protection practically does not affect the circuit, and with a high-voltage pulse, excess energy “merges” through the varistor and dissipates in the form of heat. The ability of varistors to absorb energy is not infinite, therefore, to protect against overheating, the design usually provides for a temperature sensor with an automatic switch.

Wall mount

Availability of fastening on a wall in a network filter design. Such fastening most often has the form of a characteristic eyelet (loops), designed to be put on a nail driven into the wall or other similar detail. And the installation on the wall itself is convenient in that the filter can be quite close to the user, and besides, it does not take up space on the floor (which, among other things, minimizes the risk of stepping on the device, damaging it during cleaning, etc.) .

Outlets location

Options for placing sockets on the body of an extension cord or surge protector.

- Along the hull. Devices with the layout of sockets in one slender line, which is extended along the entire body of the extension cord or surge protector.

- In 2 rows. A popular scheme with the arrangement of sockets in 2 rows is on both sides of the upper plane of the device housing.

- In a circle. This category includes all extension cords and surge protectors with sockets in the form of a full circle or a semicircle.

- On both sides of the body. Sockets on several side faces of the case are found in compact cube models and in advanced surge protectors with relocated sockets on both sides of the case, which makes it easy to connect a large number of consumer devices.
Price graph
REAL-EL RS-6 Extra 1.8m often compared