Укр|Eng|Рус
Ukraine
Catalog   /   Tools & Gardening   /   Machines & Equipment   /   Generators

Comparison Konner&Sohnen Basic KSB 40iE S vs Konner&Sohnen KS 4000iE S

Add to comparison
Konner&Sohnen Basic KSB 40iE S
Konner&Sohnen KS 4000iE S
Konner&Sohnen Basic KSB 40iE SKonner&Sohnen KS 4000iE S
Compare prices 28Compare prices 34
TOP sellers
Fuelpetrolpetrol
Output voltage230 B230 B
Rated power3.5 kW3.5 kW
Max. power3.8 kW4 kW
Alternatorinverterinverter
Alternator windingcoppercopper
Engine
ICE type4-stroke4-stroke
Motor typeKSB 240iKonner&Sohnen KS 240i
Engine size223 cm³223 cm³
Power8.5 hp7.5 hp
Launch typeelectric starter (button)electric starter (rotary)
Fuel consumption
1.53 L/h /at 50% load/
Fuel tank volume11 L12 L
Fuel level indicator
Continuous operation time
7.8 h /at 50% load/
Motor coolingairair
Connection
Number of sockets (230/400 V)22
Sockets 230 V16 A x216 A x2
Output 12 Vcigarette lightercigarette lighter
Features
Functions
 
display
hour metre
voltmeter
 
ATS socket
display
hour metre
voltmeter
parallel connection
General
Sound insulation cover
Wheels
Protection levelIP 23IP 23
Noise level96 dB
91 dB /LWA/
Sound level (7 m)71 dB66 dB
Dimensions605x475x520 mm630x475x570 mm
Weight43 kg40 kg
Added to E-Catalogseptember 2023january 2020

Max. power

The maximum power supply that the generator can provide.

This power is slightly higher than the rated power (see above), but the maximum performance mode can only be maintained for a very short time - otherwise overload occurs. Therefore, the practical meaning of this characteristic is mainly to describe the efficiency of the generator when operating with increased starting currents.

Let us remind you that some types of electrical appliances at the moment of startup consume many times more power (and, accordingly, power) than in normal mode; this is typical mainly for devices with electric motors, such as power tools, refrigerators, etc. However, increased power for such equipment is needed only for a short time; normal operation is restored in just a few seconds. And you can evaluate the starting characteristics by multiplying the rated power by the so-called starting coefficient. For one type of equipment it is more or less the same (1.2 - 1.3 for most power tools, 2 for a microwave, 3.5 for an air conditioner, etc.); More detailed data is available in special sources.

Ideally, the maximum power of the generator should be no lower than the total peak power of the connected load - that is, the starting power of equipment with a starting factor above 1 plus the rated power of all other equipment. This will minimize the likelihood of overloads.

Motor type

Model name of the engine installed in the generator. Knowing this name, you can, if necessary, find detailed data on the engine and clarify how it meets your requirements. In addition, model data may be needed for some specific tasks, including maintenance and repair.

Note that modern generators are often equipped with branded engines from famous manufacturers: Honda, John Deere, Mitsubishi, Volvo, etc. Such engines are more expensive than similar units from little-known brands, but this is offset by higher quality and/or solid warranty conditions , and in many cases, the ease of finding spare parts and additional documentation (such as manuals for special maintenance and minor repairs).

Power

The operating power of the engine installed in the generator. Traditionally stated in horsepower; 1 HP approximately equal to 735 watts.

First of all, the rated power of the generator directly depends on this indicator (see above): in principle, it cannot be higher than the engine power, moreover, part of the engine power is spent on heat, friction and other losses. And the smaller the difference between these capacities, the higher the efficiency of the generator and the more economical it is. However high efficiency affects the cost, but this difference can pay off with regular use due to fuel savings.

Launch type

Method of starting an electric generator engine. To start an internal combustion engine (gasoline or diesel, see “Fuel”), in any case, it is necessary to rotate the engine shaft; you can do this in two ways:

- Manual. With this starting method, the initial impulse is transmitted to the engine manually - usually the user needs to forcefully pull the cable that spins a special flywheel. The simplest in design and cheapest starting method, the additional equipment requires only the cable itself with a flywheel. On the other hand, it may require significant muscular effort from the user and is not well suited for high-power units.

Electric starter. With this type of starting, the engine shaft is rotated using a special electric motor, which is called a starter; The starter is powered by its own battery. This option for starting the generator power unit is the easiest for the user and requires a minimum of effort. Depending on the implementation of the electric starter, it is usually enough to turn the key in the ignition, press a button, turn a knob or spin a special drum, etc. The power of modern starters is sufficient even for heavy engines where manual starting is difficult or impossible. Also note that an electric starter is by definition required to use ATS autostart (see Features). On the other hand, additional equipment affects the weight and cost of the unit, sometimes quite...noticeably. Therefore, such starting systems are used mainly where they cannot be avoided - in the aforementioned heavy equipment, as well as generators with ATS.

Fuel consumption

Fuel consumption of a gasoline or diesel generator, and for combined models — when using gasoline (see "Fuel").

A more powerful engine inevitably means more fuel consumption; however, models with the same engine power may differ in this indicator. In such cases, it is worth considering that a model with a lower flow rate usually costs more, but this difference can quickly pay off, especially with regular use. In addition, knowing the fuel consumption and tank volume, you can determine how long one refueling will last; at the same time, in inverter models at partial load, the actual operating time may be noticeably higher than the theoretical one, see "Alternator" for details.

Fuel tank volume

The volume of the fuel tank installed in the generator.

Knowing the fuel consumption (see above) and the capacity of the tank, you can calculate the operating time on one gas station (if it is not indicated in the specifications). However, a more capacious tank is also more bulky. Therefore, manufacturers choose tanks based on the general level and "voracity" of the generator — in order to provide an acceptable operating time without a significant increase in size and weight. So in general, this parameter is more of a reference than practically significant.

As for the numbers, in low-power models, tanks are installed for 5 – 10 liters, or even less ; in heavy professional equipment, this figure can exceed 50 liters.

Continuous operation time

The time during which the generator is guaranteed to operate without interruption.

This parameter is indicated exclusively for liquid fuel models with a built-in tank, and according to the simplest formula: tank capacity divided by fuel consumption. However, in some models, data may be provided for a certain load level (which is specified in the notes); at a higher or lower load, the operating time will be shorter or longer, respectively. As for specific numbers, in most modern generators the operating time is up to 8 hours - this is quite enough for backup power and occasional use. More reputable models are capable of working for 8 – 12 hours, and an indicator of 13 hours and above is typical mainly for professional solutions.

We also note that, theoretically, many generators can be refueled without shutting down, but in practice it is better to take breaks and not exceed the stated time of continuous operation - this will avoid overheating and increased wear.

Functions

- DC output (DC 12 V). The presence in the generator of an output with direct power and a voltage of 12 V. The main function of this output is to charge car batteries, as well as power devices originally intended for cars (remember, 12 V is the standard voltage of on-board networks in passenger cars).

- USB port for charging. The generator has a USB connector (one or more) for charging various devices. Most modern smartphones and tablets can be charged from USB; this charging method is also found in many other equipment - from cameras and flashlights to electric screwdrivers and radio-controlled models. The standard supply voltage through this connector is 5 V, but the power may vary and should be specified separately.

- Synchronization with a smartphone. Synchronization with a smartphone allows you to control the operation of the generator remotely. Thanks to this, the user does not need to approach the device to, for example, start or stop it. Additionally, synchronization with a smartphone allows you to monitor the parameters of the generated electric power remotely and in real time. On the other hand, this will require a constant connection to the Internet and specialized software that must be installed on your smartphone.

- Autorun (ATS). A function that allows the generator to turn on automat...ically under certain conditions, without user action. Autostart is used mainly when using a generator as a backup power source: while the main power is on, the unit is turned off, and if the mains voltage disappears, the ATS starts the engine, and power to the load begins to flow from the generator. Note that the presence of autostart is indicated only if the generator is initially equipped with an ATS electronic unit; models with the ability to connect such a unit are placed in a separate category (see below).

- Connector for the ATS block. A connector that allows you to connect an external autorun unit (ATS) to the generator; The block itself is not included. See above for more details on autorun; We note here that for some users this function is not initially needed, but it may be needed in the future - for example, if the generator is initially used in the construction of a house, and then it is planned to be installed in the same house as a backup power source. In such situations, this configuration option will be optimal: when purchasing the generator itself, you will not have to overpay for the ATS unit, and later, if necessary, you can buy and connect such a unit separately.

- Automatic voltage regulator (AVR). An automatic regulator that allows you to maintain a constant voltage level at the generator output. Such a regulator smoothes out differences arising from changes in engine rotation speed; This is especially important when connecting devices that are sensitive to power stability. It is worth noting that the presence of AVR is practically mandatory for synchronous generators (see “Alternator”), but in other varieties this function is not found: in asynchronous and duplex units it is not applicable in principle, and in inverter units the role of the regulator is played by the inverter itself, and they do not require additional electronics.

Display. Own display mounted on the generator body. As a rule, this is a simple LCD screen that can only display numbers and some special characters. However, even such a screen can display various useful information: voltage, frequency, hour meter data, low fuel level warning, failure messages with error codes, etc. Thanks to this, control becomes more convenient and visual.

- Hour meter. A device that counts the total time that the electric generator engine has worked since it was first turned on. This helps to determine the general wear and tear of the engine and the need for its repair/replacement, which can be useful both when using the device for a long time, and, for example, to assess the quality of the product when purchasing a used electric generator. It is usually impossible to reset the hour meter without serious intervention in the design of the device.

Voltmeter. A device that displays the power voltage output by the generator. The voltmeter can be made in the form of a separate dial scale, or its readings can be displayed on the generator’s own display (see above). In any case, this function allows you to carefully control the operating mode of the unit and reduces the risk that unacceptable voltage will be applied to the load.

- Parallel connection. The presence in the design of the generator of special connectors through which two or more units can be connected to a single electrical network (usually with the help of an additional device). This type of connection is used when one unit is not able to pull the entire load and the connection power exceeds the capabilities of the device itself. Also, a similar scheme has found popularity if one of the units is planned to be used as a backup power source.

- Remote start. Presence in a set of delivery of the generator of the remote control. It is made in the form of a wireless key fob and allows you to turn on/off the device from a distance without going near it.

Noise level

The noise level produced by the generator during normal operation. The less noise the unit makes, the more comfortable it is to use, the closer it can be placed to people, but the higher its price, all other things being equal.

It is also worth considering that generators with internal combustion engines are, in principle, quite noisy equipment. So, even the “quiest” units produce up to 70 dB - this is the volume of conversation in tones from medium to high. Accordingly, it is recommended to install the device remotely from the place of use. At the same time, we note that the noise level is not directly related to power: for example, among units with 80 dB or more, there are both heavy and relatively low-power models.
Price graph
Konner&Sohnen KS 4000iE S often compared