Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Generators

Comparison Brevia GP2500iS vs Brevia GP2300iS

Add to comparison
Brevia GP2500iS
Brevia GP2300iS
Brevia GP2500iSBrevia GP2300iS
Compare prices 6Compare prices 8
TOP sellers
Fuelpetrolpetrol
Output voltage230 B230 B
Rated power2.3 kW1.8 kW
Max. power2.5 kW2 kW
Alternatorinverterinverter
Alternator windingcoppercopper
Engine
ICE type4-stroke4-stroke
Engine size143 cm³80 cm³
Fuel consumption (75% load)0.85 l/h
Fuel tank volume7 L7 L
Starter typemanualmanual
Motor coolingairair
Connection (sockets)
Total number of sockets22
Sockets 230 V16 A x216 A x2
USB charging port
Output 12 Vsocketsocket
Features
Features
display
hour metre
voltmeter
parallel connection
display
hour metre
voltmeter
parallel connection
General
Sound insulation cover
Wheels
Protection levelIP 23IP 23
Sound level (7 m)61 dB61 dB
Weight23.5 kg20 kg
Added to E-Catalogoctober 2023october 2023
Brief conclusions of the comparison generators

Price graph
Glossary

Rated power

The nominal power of a generator is the highest power that the unit can supply without problems for an unlimited period of time. In the “weakest” models, this figure is < 1 kW, in the most powerful ones – 50–100 kW and even more ; and generators with welding capabilities (see below) usually have a nominal power from 1–2 kW to 8–10 kW.

The main rule of choice in this case is as follows: the nominal power must not be lower than the total power consumption of the entire connected load. Otherwise, the generator will simply not be able to produce enough energy, or will work with overloads. However, to determine the minimum required generator power, it is not enough to simply add up the number of watts indicated in the characteristics of each connected device - the calculation method is somewhat more complicated. Firstly, it should be taken into account that only the active power of various equipment is usually indicated in watts; in addition, many AC electrical appliances consume reactive power ("useless" power consumed by coils and capacitors when working with such power). And the actual load on the generator depends on the total power (active plus reactive), indicated in volt-amperes. There are special coefficients and formulas for its calculation.

The second nuance is related...to the power supply of devices in which the starting power (and, accordingly, the power consumption at the moment of switching on) is significantly higher than the nominal one - these are mainly devices with electric motors such as vacuum cleaners, refrigerators, air conditioners, power tools, etc. You can determine the starting power by multiplying the standard power by the so-called starting coefficient. For equipment of the same type, it is more or less the same - for example, 1.2 - 1.3 for most power tools, 2 for a microwave oven, 3.5 for an air conditioner, etc.; more detailed data can be found in special sources. Starting load characteristics are necessary primarily to assess the required maximum generator power (see below) - however, this power is not always given in the characteristics, often the manufacturer indicates only the nominal power of the unit. In such cases, when calculating for equipment with a starting coefficient of more than 1, it is worth using the starting power, not the nominal power.

Also note that if there are several sockets, the specific division of the total power between them may be different. This point should be clarified separately - in particular, for specific types of sockets (for more details, see "230 V sockets", "400 V sockets").

Max. power

The maximum power output that the generator can provide.

This power is slightly higher than the nominal (see above), but the maximum performance mode can only be maintained for a very short time - otherwise an overload occurs. Therefore, the practical meaning of this characteristic is mainly to describe the efficiency of the generator when working with increased starting currents.

Let us recall that some types of electrical appliances consume several times more power (and, accordingly, power) at the moment of starting than in the normal mode; this is typical mainly for devices with electric motors, such as power tools, refrigerators, etc. However, increased power for such equipment is needed only for a short time, normal operation is restored in literally a few seconds. And you can estimate the starting characteristics by multiplying the nominal power by the so-called starting coefficient. For equipment of the same type, it is more or less the same (1.2 - 1.3 for most power tools, 2 for a microwave oven, 3.5 for an air conditioner, etc.); more detailed data is available in special sources.

Ideally, the maximum power of the generator should be no less than the total peak power of the connected load - that is, the starting power of equipment with a starting factor greater than 1 plus the rated power of all other equipment. This will minimize the likelihood of overloads.

Engine size

The working volume of the engine in a gasoline or diesel generator (see "Fuel"). Theoretically, more volume usually means more power, but in fact, everything is not so clear. Firstly, the specific power strongly depends on the type of fuel, and in gasoline units, also on the type of internal combustion engine (see above). Secondly, similar engines of the same power can have different volumes, and there is a practical point here: with the same power, a larger engine consumes more fuel, but by itself it can cost less.

Fuel consumption (75% load)

Fuel consumption of the generator at 75% load (75% of the nominal power of the power unit). The amount of fuel consumed is indicated for gasoline and diesel models, as well as units on combined fuel (in this case, gasoline consumption is usually implied).

Since the generator's efficiency is not always linear, fuel consumption may vary disproportionately with different loads. In this case, the amount of fuel consumed by the generator when operating with a load of about 75% of the nominal power is given. Knowing the fuel consumption and tank volume, you can roughly estimate how long one fill will last.

Weight

The total weight of the unit - usually excluding fuel; the weight on full tank can be easily determined knowing the tank capacity.

In general, more powerful generators are inevitably heavier, but models with similar characteristics can differ significantly in weight. When assessing these differences and generally choosing an option based on weight, it is worth considering the specifics of the generator's use. So, if the device is often to be moved from place to place - for example, when used "on the road" - it may be worth paying attention to lighter units that are more convenient to transport. However, it is worth considering that the downside of a lightweight design is often an increased cost or a reduced degree of protection. But for stationary use, you can not pay special attention to this parameter - or even the opposite: choose a heavier (and, as a rule, more advanced and functional) option.

Regarding specific figures, it is worth noting that modern generators are generally quite massive. Thus, a small weight for such equipment is considered not only < 20 kg, but even 20-30 kg ; many units weigh 150-200 kg, or even more, and the weight of stationary industrial models is measured in tons.