1. AMP is the name of the series. Options: Amp, Hertz, Hertz Duo, Hertz O, Hybrid;

  • Amperes - single-phase, up to 40 A (9 kVA) triac, after 50 A (11 kVA) thyristor
  • Hertz - single-phase: up to 40 A (9 kVA) triac, after 50 A (11 kVA) thyristor; three-phase: all thyristor;
  • Hertz Duo - single-phase, up to 40 A (9 kVA) triac, after 50 A (11 kVA) thyristor; two lines on the information display;
  • Hertz O - three-phase industrial thyristor;
  • Hybrid - single-phase, combined (triac + relay).

2. -P - modification of the stabilizer; there is no index for the standard modification, -P - extended input voltage range relative to the standard one, T - precise: high accuracy of the output voltage relative to the standard one.

3. 16 - the number of switching stages of the control transformer; possible options: 7, 9, 12, 16, 36(usually, the greater the number of switching steps, the higher the accuracy of the output voltage).

4. 1 - number of phases; options: 1 - for single-phase models (220 V), 3 - for three-phase models (380 V).

5. /25 - rated input current in amperes; options: from 5 to 100 A; 5 A corresponds to a power of 1.1 kVA, 25 A corresponds to a power of 5.5 kVA, etc.

6. v2.0 - model execution version.