Beretta EXCLUSIVE 28 CAI 28.3 kW

Photos - Boiler Beretta EXCLUSIVE 28 CAI 28.3 kW
Outdated Product
23 300 
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 212; Heat output (kW): 28.3; Coolant min. T (°C): 40; Coolant max. T (°C): 90; DHW min. T (°C): 35; DHW max. T (°C): 60; Performance (ΔT=25 °C) (L/min): 16.2; Efficiency (%): 90.4; Combustion chamber: open (atmospheric)
add to listmy lists
Beretta EXCLUSIVE 28 CAI 28.3 kW
24 kW
28.3 kW
Energy source:gas
Mount:wall, dual-circuit
Boiler power:28.3 kW, area ~ 212 m²
Combustion chamber:open, flue 130 mm
DHW temperature:from 35 °С, up to 60 °С
All specifications
Specifications EXCLUSIVE 28 CAI
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area212 m²
Technical specs
Heat output28.3 kW
Power supply230 В
Power consumption85 W
Coolant min. T40 °С
Coolant max. T90 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure6 bar
Consumer specs
DHW min. T35 °С
DHW max. T60 °С
Performance (ΔT=25°C)16.2 L/min
Performance (ΔT ~30 °C)11.6 L/min
"Summer" mode
Circulation pump
Boiler specs
Efficiency90.4 %
Combustion chamberopen (atmospheric)
Flue diameter130 mm
Inlet gas pressure20 mbar
Max. gas consumption3.31 m³/h
Expansion vessel capacity8 L
Expansion vessel pressure1 bar
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply3/4"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
flame loss
power outage
frost protection
More specs
Dimensions (HxWxD)740x400x332 mm
Weight33 kg
Added to E-CatalogSeptember 2010
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Beretta 2025 - new arrivals, bestsellers, and the most relevant models Beretta.
larisa
8 February 2012, 19:12
Question about Beretta EXCLUSIVE 28 CAI 
Какова возможная причина неполадки при коде 01?
Включено положение колонка+котел, включаем горячую воду-все нормально,переключаем на отопение огонь не загорается, давление и температура воды падает и выключается с кодом 01.Также может выключаться сам по себе с кодом 01.Что это?
anonim
21 May 2020, 19:03
Question about Beretta EXCLUSIVE 24 CAI 
Настенный котёл Беретта. Электрод розжига постоянно находится в рабочем состоян
anonim
22 November 2015, 20:24
Question about Beretta EXCLUSIVE 24 CAI 
Не нагревает гарячую воду
3 out of 6 question(s) shown
3 more question(s)
Filters