Укр|Eng|Рус
Ukraine

RUCELF UPI-1000-12-E 1000 VA

Photos - UPS RUCELF UPI-1000-12-E 1000 VA
6 700 
  
Buy!
Technofox.com.ua

ИБП RUCELF UPI-1000-12-E

Technofox.com.ua
6 year with us
(Kyiv)
Warranty: 12 month
Report
add to listmy lists
RUCELF UPI-1000-12-E 1000 VA
400 VA1000 VA
Main
Typesmart
Form factorstandard (Tower)
Half load operating time5 min
Switching to battery4 ms
Input
Input voltage1 phase (230V)
Input voltage range140-270 V
Input frequency45-55 Hz
Bypass (direct connection)is absent
Output
Output voltage1 phase (230V)
Max. output power1000 VA
Rated output power600 W
Output waveformsimilar to a sinusoid (approximated)
Output frequency50-60 Hz
Redundant sockets2
Socket typetype F (Schuko)
Battery
Battery connection voltage12 V
Batteries1
Full charge time600 min
Cold start
External battery connection
Protection
Protectionshort circuit protection
overload protection
noise filtering
sound alarm
Fuseauto
General
Operating temperature0 – 40 °C
Dimensions (HxWxD)190x120x320 mm
Weight11 kg
Added to E-Catalogdecember 2015

Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog RUCELF 2024 - new products, best sales and most actual models RUCELF.
i'm looking for a normal UPS and I can't find it!!! [censored] - Chinese conspiracy!!!!
  
For 4 years killed two batteries - regular and gel
didn't notice
The battery charge voltage is not regulated ... it fries up to 14.8 volts and the battery is garbage
Сергейuse RUCELF UPI-1000-12-E more than year
normal model, nothing special
  
The device is a bit overpriced. The UPS has several drawbacks that seriously spoil the impression of using the device. It seems that the device is unfinished, because. sickness is just childish.
The case of the device is made quite well and leaves only pleasant impressions. Large, easy-to-read display shows voltage level. The indicators signal the currently used modes. There is a button that disables the alarm. It uses inverter technology to adjust the voltage level. A charged battery provides energy in case of a drawdown so that the equipment receives a stable level of current. There is protection of the connected equipment from overloads, so you can not worry about its performance.
Some oddity has been noticed. If the battery is discharged, then the indicator does not signal this. The fan stops working - this is the only sign of a lack of energy in the battery. Moreover, the cooling system functions constantly, even if it is not needed. You can't stop the fan either. And he makes a decent noise, so his work is often annoying. The power button is quite flimsy, it can fall off at any time. I did not find the function of protecting the battery from overcharging in the characteristics, so it is not clear how long the batteries will last. I have been using the UPS for a month, and so far everything is working, however, the batteries, I suspect, will not last long.